Solution |
|
- Check whether the previous plate is stuck in the processor.
- Plate is not stuck in processorproceed to step 2.
- Plate is stuck in processorthe plate may be blocking the conveyor
sensor. Verify that the processor is in Ready state, and reset
to clear any error messages on the processor panel. If the problem
persists, contact the processor technician.
- Manually move the previous plate into
the processor.
- From the Routine Functions menu, click Unload Plate
and manually unload the current plate.
- Check if there are error messages relating to vibration or fly-off.
- If there are such messages, contact your service representative.
- If there are no error messages, proceed to step 5.
- Load another plate and check if it unloads smoothly.
- If the plate does not unload smoothly, remove the stuck plate,
and try to load and unload a plate of a different size. If this
is successful, there may be a specific problem with the original
plate size.
- If the plate unloads smoothly, contact your service representative.
- Examine the plate to see if it was partially exposed, or not exposed
at all.
- Plate is correctly exposedproceed to step 7.
- Plate is partially exposed, or not exposedpartial exposure
indicates a problem with the exposure sequence.
- Check whether the unload gripper
was activated or not:
- In the Hardware tree, select Drum
System > Gripper system > Unload Gripper, and then double-click
Unload Gripper Enable Detector.
- In the Unload Gripper Enable Detector
dialog box, check the detector status.
- If the detector status is ONproceed
to step 8 to check the unload drum position.
Note: The unload gripper enable detector is ON when
the drum is at unload position and the tail gripper is under the
unload gripper actuator.
- If the detector status if OFFcheck the following:
- Silver reflecting tapeif there is no tape, replace the
tape.
- Detectorif the detector is defective, replace the detector.
- Check the unload drum position:
- In the Hardware tree, select Drum
System, and then double-click Drum Motor.
- In the Motor dropdown list,
select Unload Motor, and then record the unload position.
- In the Hardware tree, select Others,
and then right-click Lotem 400 to view the Properties dialog
box.
- In the Properties Lotem400 dialog
box, double-click +MACHINE.
- In the Properties Lotem400\MACHINE
dialog box, in the Unload Head Gripper Location row, type the unload
position that you recorded in step 8b.
|