Connectivity-related error message appears on Lotem 400


Product

 

Lotem® 400


Error

 

Error messages related to connectivity, such as:

  • No communication
  • Host connection server task failed.
  • Host requests server task failed.
  • Invalid Host Request: %s
  • Host requests server task exit due to timeout.
  • Wait for start expose time out.

Cause

 
  • Loose cable connections
  • Incorrect IP address
  • TSP board malfunction

Solution

 
  1. In Brisque, in the Output Device Configuration dialog box, select Boards and click Reset TSP Board.
  2. Verify that the data cable is securely connected to the workstation.
  3. Verify that the Network cable (Point-to-Point cable) between the platesetter and the workstation is properly connected.
  4. To check if you have a TCP/IP dialing connection from the dialing PC to the platesetter, from the workstation, open a command line and run the ping command:
    On the PC, select Start > Settings > Control Panel > Network > TCPIP > Properties and type ping 192.9.200.2
    Note: To stop the ping sequence, type CTRL + C.
  5. Replace the TSP board.