Product

 

Lotem® 400 Xpose with UDRC LC configured


Component

 

NUC board revision C


Error

 
  • UDRC error:Debris Removal Fatal software error.
  • UDRC error:The udrc start opration failed.
  • The task udrc:switch on switch failed.

Cause

 

Revision of NUC board


Solution

 

Remove the NUC board revision C and install NUC board revision D.

Note: The part number of the NUC board remains the same, 503C2L182P.


Technical contact(s)
 

Mario Amir

Submitted by
 

Mario Amir

Date submitted
 

15 Apr 2004