Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Loading a patch to TMCE


Product

  Lotem 400 Quantum

Background

 

The following procedure describes how to load a patch to TMCE. 


Procedure

 
  1. Open the Splot terminal.
    The Quantum>> prompt appears.
  2. Type reset boot.
    (Quantum>>reset boot)
    The Boot>> prompt appears.
  3. Quit the Splot terminal to free the serial port.
  4. Open a DOS prompt and type cd \th2\tools.
    (C:\>cd \th2\tools)
    The C:\TH2\Tools> prompt appears.
  5. Type bload f=mcelca0137.bin p=8 i=ica.
    (C:\TH2\Tools>bload f=mcelca0137.bin p=8 i=ica)
  6. After the file completes loading successfully, 
    type cd \th2\tools
    (C:\>cd \th2\tools)
    The C:\TH2\Tools> prompt appears.
  7. Type bload f=QuantumFmw120-05.bin p=8 i=main
    (C:\TH2\Tools>bload f=QuantumFmw120-05.bin p=8 i=main)
  8. After the file completes loading successfully, open the Splot terminal.
    The QUANTUM>> prompt appears.
  9. Type reset.
    (QUANTUM>>reset)
    The Quantum>> prompt appears.
  10. To verify the new minimum size, type product.
    (Quantum>>product)

 