Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Dents in 0.15 mm plates on Lotem 400 Quantum with MCU


Product

 
  • Lotem® 400 Quantum
  • MCU for Lotem 400
  • Lotem Controller 1.50.08

Symptoms

 

Dents in 0.15 mm plates


Cause

 

The script disregards the Y Down After Punch For 0.15 parameter and uses the Y down after punch parameter instead.


Solution

 

After the XY bar reaches 765 mm on the X axis, it descends to 9 mm (relative) on the Y axis. Change the parameters that control these movements to resolve denting on 0.15 mm plates.

  1. In Regedit, locate ...\IO OBJECTS\Loading System \Load Plate\From Cassette To Punch Entry Stage.
  2. Decrease the Y down after punch (mm) parameter by a few milimeters (default = 9).
  3. Optional: increase or decrease the following parameters by a few milimeters:
    • X In After Punch (mm)—(default = 755)
    • X Move X Upto wheels for 015 (mm)—(default = 10)

See also

 

Update 3, which will resolve this problem, is currently in Field Test status.
See the Downloads page to check whether this update has been released.
Note: You will need to update this item when Update 3 is released.


Technical contact(s)
 

Mario Amir

Submitted by
 

Mario Amir

Date submitted
 

21 Jul 2004