Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Field Change Order #24804 - Metal Nipples for Cassette Air Pressure

Description

Replacing the air pressure angled plastic nipples with a metal nipples

Prepared By: S. Avisror FCO Kit No.: 510F24804
Comp. Level: N/A Machine S/N: Lower Then 9826XXXX
Catalog No. N/A S/W Affected: N/A
Type of Change: Conditional Total Number of Pages:2
Product Mgr: N. Halup Approval Date: 11/16/98
Product Support: S. Avisror Approval Date: 11/16/98
Customer Support Mgr: Kuty Paperny Approval Date: 11/16/98
  1. Reason For Change - Original nipple made from plastic and later discovered that it had a tendency to break.
  2. Description of Change - Replace plastic nipples with metal nipples.
    The angled plastic nipples that need to be replace is behind the rollers assembly in the location by the arrow (can't be seen in the photo)
  3. Change Procedure -
    1. In order to access the angled nipple on the back of the injector, you need to access the back of the roller assembly in order to disconnect the injector from the nipple.
    2. Replace the plastic nipple with the metal nipple.
    3. Tighten the injector to the nipple.
  4. Test Procedure - Insert the loading cassette and check that the
    air is activated correctly during plate loading.
  5. Parts List -
    290A5L671 x 2
    344C70010 x 2
  6. Attached Documentation - None
  7. Material Disposition - None
  8. Logistics -
    STA can order up to 11 kits
    STE can order up to 11 kits
    STAP can order up to 3 Kits
    STN can order up to 1 Kit
    STME can order up to 1 Kit

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.