Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Type of Change: Conditional
Machine S/N: Q3 / Q4 , 98
Replace the disposal door locker with a new locker in order to better tighten the door to the main frame.
Replacing the locker male and female and the detector flag of the left and right disposal door.
Replace the male locker, female locker and the detector flag with a new one that you received with the FCO. Follow the picture.

Check that the disposal door is secured to the main frame and that the status of the disposal door (right and left) change accordingly from off to on.
290A7L904 |
PAPER INT. ADAP.-2 |
| 290D9L324 | DOOR LOCKER MALE-NEW |
| 387B00010 | TWIN BALL CATCH H=60MM BRASS |
N/A
You may dispose of the old locker
STA 30 STE 30 STAP 5 STN 5 STMA 5