Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Field Change Order #25178 - Disposal Door Locker

Sammy Avisror
March 1, 1999

Type of Change:  Conditional
Machine S/N:  Q3 / Q4 , 98

Reason for change

Replace the disposal door locker with a new locker in order to better tighten the door to the main frame.

Description of change

Replacing the locker male and female and the detector flag of the left and right disposal door.

Change procedure

Replace the male locker, female locker and the detector flag with a new one that you received with the FCO. Follow the picture.

New Locker for the disposal door

lot1.jpg (39740 bytes)

Test Procedure

Check that the disposal door is secured to the main frame and that the status of the disposal door (right and left) change accordingly from off to on.

Parts List

290A7L904

PAPER INT. ADAP.-2
290D9L324 DOOR LOCKER MALE-NEW
387B00010 TWIN BALL CATCH H=60MM BRASS

Attached Documentation

N/A

Material Disposition

You may dispose of the old locker

Logistics

STA    30
STE    30
STAP    5
STN     5
STMA    5

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.