| Prepared By: Gabi Ra'anan | FCO Kit No.: 510F27384 |
| Comp. Level: N/A | Machine S/N:N/A |
| Catalog No. : 27624 | S/W Affected: N/A |
| Type of Change: Conditional | Total Number of Pages: ? |
| Product Mgr: Nir Halup | Approval Date: |
| Product Support: Gabi Ra'anan | Approval Date: Apr. 19,2001 |
| Customer Support Mgr: Kuty Paperny | Approval Date: |
Installation of a stopper beneath upper tray.
3.1 Remove 4 upper screws on each side of the upper tray [see photo # 4306].
Note:Do not remove the lower screws that attach the rails to the
cover as it requires readjustment of the rails and upper tray !
3.2 Position the red jig supplied as shown in the drawing (422 mm from right
the edge) [P.# 4307] .Drill 3/16 (or 4.5 mm) holes through the jig.
Note: Place a paper sheet in the lower compartment to collect the
chips from the drilling!
3.3 Raise the lower compartment cover and install the stopper; It's attached
with two 8/32x5/8 scerws to a small threaded bar which you have to insert
through the beam under the cover [P.# 4308,4309]. Use Blue Loctite 242.
3.4 Install the upper tray and use Loctite to secure the screws.
Move the tray up and down couple of times and ensure smooth operation.
Load few plates
And verify proper loading on the drum.
| PART |
QTY
|
| 290B6B337 | 1 |
| 290B6B329 | 1 |
| 290A6B338 | 1 |
| 380A05081 | 2 |
| 382D10000 | 2 |
Approved quantities:
| CSA | : | 5 |
| CSE | : | 5 |
| CSAP | : | N/A |
| CSN | : | N/A |
| CSMA | : | 3 |
| Other | : | |
| No Limit |