Field Change Order #27647 - Local 3 Box

Description To improve reliability of the Local 3 board replacement.

Prepared By: Ze'ev Rozenberg

FCO Kit No: 510F27647

Comp. Level:

Machine S/N:

Catalog No:

S/W Affected:

Type of Change: Conditional

Total Number of Pages: 4

Product Mgr: Nir Halup

Approval Date:

Product Support: Itai Peperovich

Approval Date: 24-JUL-2001

Customer Support Mgr: Assaf Zach

Approval Date:

1. Reason For Change

2. Description of Change

Replace the Local 3 box with a new designed box.

3. Change Procedure

1. Remove the four screws from the Local cover (picture 1).

2. Disconnect the fan connector from the board.
3. Disassemble the fan from the old cover and assemble it on the new box cover.
4. Remove the Local board by opening six screws (picture 2).

Note: Make sure the isolation sheet is ONLY installed in the black & white boxes (picture 3).

6. Connect the fan connector.
7. Close the Local box cover with four screws.

4.Test Procedure

None.

5. Parts List

PART

QTY

294A2M919A

LOCAL 3 BOX SUB ASSY
374A00080 PACKING LABEL-WHT
7!FCO-DOC FCO DOCUMENT

6. Attached Documentation

None.

7. Material Disposition

Dispose of the old Local boxes.

8. Logistics

8.1 Approved quantities:

CSA

:

50

CSE

:

20

CSAP

:

 

CSN

:

 

CSMA

:

 

Other

:

 
No Limit    

8.2 Schedule supplies for first lots

D.U

 

Month

QTY

Month

QTY

Month

QTY

CSA

:

August 20 September 30    

CSE

:

August 15 September 5    

CSAP

:

August 5        

CSN

:

August 5        

CSMA

:

August 5        

Other

:

           

8.3 Inventory in warhouses:

Replace all boxes currently in the inventory.


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.