Appendix D – Different configurations Registry parameters

Note: The path for all the following parameters is Scitex/Projects/Lotem 800/ i.e. the path at the Registry. If you have to change any of the following components after installing this version, you need to change the corresponding Registry parameters according to this table.

Combinations of Local boards and XY system:

Local3,always new XY System Value Default
MACHINE\ XY System Type (Old=0,Spring Stretch=1) 1 1
IO OBJECTS\ LOCAL 3\ DC MOTORS\X Motor\ Min Speed App Value 0.1 0.1
IO OBJECTS\ LOCAL 3\ DC MOTORS\ X Motor\ Pos Factor 0.00141172 0.00141172
IO OBJECTS\ LOCAL 3\ DC MOTORS\ X Motor\ Home Pos Operate Value   40 40
IO OBJECTS\ LOCAL 3\ DC MOTORS\ Y Motor\ Pos Factor 0.00135 0.00135
Local2,New XY System Value Default
MACHINE\ XY System Type (Old=0,Spring Stretch=1) 1 1
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ X Motor\ Min Speed App Value -127 -127
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ X Motor\ Pos -0.00569353 -0.00569353
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ X Motor\ Home Pos Operate Value 180 180
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ Y Motor\Pos Factor 0.00565667 0.00565667
Local2, Old XY System, New X Motor Value Default
MACHINE\ XY System Type (Old=0,Spring Stretch=1) 0 1
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ X Motor\ Min Speed App Value 0.01 0.01
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ X Motor\ Pos Factor 0.0045 0.0045 
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ X Motor\ Home Pos Operate Value 40 40
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ Y Motor\ Pos Factor 0.00441927 0.00441977
Local2, Old XY System, Old X Motor Value Default
MACHINE\ XY System Type (Old=0,Spring Stretch=1) 0 1
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ X Motor\ Min Speed App Value 0.01 0.01
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ X Motor\ Pos Factor 0.00477252 0.0045
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ X Motor\ Home Pos Operate Value 40 40
IO OBJECTS\ NEW LOCAL\ DC MOTORS\ Y Motor\ Pos Factor 0.00441927 0.00441927

Note: The default parameters are for the new X motor.

Strobe Card

  1. Strobe7 card:
    IO OBJECTS\ DDB CARDS\ DDB Card\ Maximum DDB Divider = 1
    IO OBJECTS\ STROBE CARDS\ STROBE\ Strobe Card\ Open = 0
    IO OBJECTS\ STROBE CARDS\ STROBE7\ Strobe Card\ Open = 1
  2. Strobe5 card:
    IO OBJECTS\ DDB CARDS\ DDB Card\ Maximum DDB Divider = 32
    IO OBJECTS\ STROBE CARDS\ STROBE\ Strobe Card\ Open = 1
    IO OBJECTS\ STROBE CARDS\ STROBE7\ Strobe Card\ Open = 0

Screen Processor Card

  1. VLSI card:
    MACHINE\ Screen Processor Type(VLSI=0 , TSP=1) = 0
    IO OBJECTS\ DDB CARDS\ DDB Card\ Hex File Name =
    Lotem800\UpLoadFile\Ddb\VLSI\ddb-wcs.hex
  2. TSP card:
    MACHINE\ Screen Processor Type(VLSI=0 , TSP=1) = 1
    IO OBJECTS\ DDB CARDS\ DDB Card\ Hex File Name =
    Lotem800\UpLoadFile\Ddb\TSP\ddb-wcs.hex

Mcf Card

  1. Revision A:
    IO OBJECTS\ MCF CARDS\ MCF Card\ Xilinx File = Lotem800\UpLoadFile\Mcf\ctp.xil
  2. Revision C:
    IO OBJECTS\MCF CARDS\ MCF Card\ Xilinx File = Lotem800\UpLoadFile\Mcf\ctp_RevC.xil

Distribution Card

  1. Revision B:
    MACHINE\ Distribution Revision (B=0,C=1) = 0
    IO OBJECTS\ DISTRIBUTION CARDS\ Distribution Card/ DETECTORS\
    Drum Vibration Activated\ Detector Number = 4
    IO OBJECTS\ DISTRIBUTION CARDS\ Distribution Card\ DETECTORS\
    Fly Off Activated\ Detector Number = 5
  2. Revision C:
    MACHINE\ Distribution Revision (B=0,C=1) = 1
    IO OBJECTS\ DISTRIBUTION CARDS\ Distribution Card\ DETECTORS\
    Drum Vibration Activated\ Detector Number = 31
    IO OBJECTS\ DISTRIBUTION CARDS\ Distribution Card\ DETECTORS\
    Fly Off Activated\ Detector Number = 4

0.15 mm plate thickness kit

DSM

  1. Dsm:
    IO OBJECTS\ MCF CARDS\MCF Card\CARRIAGE\ Carriage Motor\ Stepper Factor = 2048
  2. Dsm2:
    IO OBJECTS\MCF CARDS\MCF Card\CARRIAGE\ Carriage Motor\ Stepper Factor = 3984