The Lotem 800Final ATP file is shown on the
next page. The file contains the following elements (the numbers below refer to the
element numbers in the figure):
CreoScitex B/W Page, see detailed description
further on.
CreoScitex Digital Target (SDT) for testing
various parameters on a positive plate; see detailed description below.
2a. CreoScitex Digital Target (SDT) for testing various parameters
on a negative plate; see detailed description below.
Plate areas with 50% dot percentages. To check the density
uniformity and plate development process.
Target of squares in check pattern. The cleanliness of the
exposure and development is determined by examining the white and black squares.
The four plate corners represent the density.
Target of squares in various sizes, ranging from 1P to 4P.
To determine the exposure quality.
Gray scale from 0% to 100%, in 21 levels of 5%, to check the
Excurve (linearity) and dot quality.
Vertical vignette to check the smoothness from 0% to 100%.
Row of slashes (at the top) and a row of backslashes (at the
bottom). To check that the lines are uniform and not jagged.
Four corners with circles for checking focus.
Text of various thickness, for positive and negative.
Horizontal vignette to check the smoothness from 0% to 100%
(as in 8).
Figure 6-1 shows the Lotem 800 Final ATP
file.