Symptoms |
The critical performance of the platesetter is erratic. |
|||||||||||||||||
Cause |
The performance of the platesetter can be greatly affected by an unstable power supply, for example outages, sags, surges and bad harmonics. |
|||||||||||||||||
Solution |
The problem created by an unstable power supply can be resolved by connecting
either a Power Conditioner or an Uninterruptible
Power Supply (UPS). Power Conditioner: Also called a line
conditioner, a power conditioner is a device that sits between a power
supply (for example a wall outlet) and the platesetter. The power conditioner
not only provides protection against surges in power but it also maintains
a continuous voltage fed to the platesetter during temporary voltage reductions,
such as a brownout. This is referred to as conditioning. Power
conditioners can also filter electromagnetic interference (EMI) emanating
from a power source and can smooth the rhythmic cycle of alternating current. Uninterruptible Power Supply (UPS): The UPS is a device that sits between a power supply and the platesetter. The UPS has internal batteries to guarantee that continuous power is provided to the equipment even if the power supply stops providing power. The UPS can provide power for a while, albeit a few minutes, but that is often long enough to ride out power company glitches or short outages until an external generator starts up. UPS devices are more expensive than power conditioners because they must contain enough batteries to support a platesetter for those critical few minutes until the generator takes over. The table below describes the UPS / power conditioner and main circuit
breakers requirements:
Note: The values above include the multi-cassette unit. In addition to the various UPS/power conditioner requirements, different Lotem processes require different amounts of Kilo Volts Amps (KVA). For example, more KVA is needed to rotate the drum (high peak) than for exposing plates.
|
|||||||||||||||||
See also |
For more information regarding a Lotem's electrical requirements, see the Lotem 800 Family Site Preparation Guidelines. |
|||||||||||||||||