The correct method
for loading DDB–1N software and subsequent startup procedure. This procedure
is in response to increased service calls associated with DDB failures in the
field.
Make sure that the L-BOX main power
switch is on.
Open the application and make sure
that the machine is in ready mode.
Open the DDB dialog box under Hardware/Boards/DDB
card.
In the DDB dialog box press the Connect
button.
Make sure that the status is Open
O.K. (Checks communication to DDB).
In the DDB dialog box, press the Send
all button and wait about two minutes.
At the end of operation, the following error message appears: DDB
card returned illegal buffer
length (opcode 83 returned 0 expected 2 to 2). The
machine will be in ATTENTION mode.
Close the DDB dialog box.
Open the Lotem 800 rear door using the
application. Wait a moment for the solinoids to release and then go to the Lotem.
Close the door and return to the application. .
Under
Hardware/Boards/DDB card open
the DDB dialog box again.
Press the Connect button in the DDB dialog box.
Under the DDB status box, select FPGA
status register – 0.
If the S/W loading and startup is O.K the status of the register should be: 000
FF FF F7 F7.
If a different status appears, repeat the
procedure. If the procedure fails again, replace the DDB board and repeat the
procedure.
Perform laser calibration and make sure all
diodes are calibrated.
Expose a customer job and check laser quality.