Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Drum Motor Replacement

Iris Kadosh
17-Oct-00

In order to perform this procedure you need to have the following 

Instrument:

Torque of 1000 kg/cm drives 3/8.
Torque of 350 kg/cm drive 3/8.
Lock tight 262
Lock tight 242

It will help if you will have also dagesh to knock on the bore that will break the Loctite so it will be much easier to pull the motor out.

Preparation

Clean the axis that the motor set on.
Make sure that between the motor stator and the rotor there is insulated.

Operation

Insert the motor on the axis make sure that you inserting the motor smoothly on the axis. Put lock tight 242 on the 6 screw of 3/8-24 x 1 1/4 and close crossbreeding. Take out the insulated. Assemble on the axis the correlation unit to close the motor and on it assemble the nut. The nut should be with locktight262. Close the nut with the jig use torque of 1000 kg/cm. Connect the electric wiring to the motor. Connect the vacuum unit of the drum on the long axis.