Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Adjusting the Centering System Factor Parameter in the Registry

  1. Click to open Loading System > Centering System >Centering Motor
  2. Select the Centering Motor and click the right mouse button to reach registry :
  1. Execute Save ® Send.
  2. Place a plate manually in the centering system with known size and perform centering (Punch/Cent) 5 times.

    Note: During the "Centering" make sure that the plate is straight along both axes.
  1. In order to perform HP for the Centering system you must use the HP Detector option.
  2. Calculate the average value of the 5 results from this position.
  3. Enter the result into the following formula :
Virtual HP = ( Value from step 6 ) * ( -0.010613 ) – ( Plate Size )
  1. Enter the value into Loading System > Centering System > Centering Motor > Virtual H.P. APP Value.
  2. Re-enter the original value into Pos Factor =(-0.010613 ) and then execute Save ® Send.
  3. Check a number of plate sizes, by performing centering, Verify that the value received in the Centering Motor window is correct.

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.