Purging the Air Supply in the Lotem 800
To purge the air supply:
- In the GUI, move the carriage to position 200, as follows:
- Select Utilities > Hardware.
- In the displayed Hardware tree, double-click Expose
System > Carriage System > Carriage Motor.
- In the Operation tab of the Carriage Motor
dialog box, select Position and type
200
in the Position field.
- Click Start.
- In the GUI, activate the lens air valve, as follows:
- In the hardware tree (under Expose System), double-click Laser
System > Lens Air Valve.
- In the Operation tab of the Lens Air Valve
dialog box, click Start.
- Allow the air to circulate for at least five minutes in order to
clear all accumulated moisture and dirt from the system, and
then click Stop.
- Activate the Cassette In and Cassette Out air valves, as follows:
- In the hardware tree, double-click Loading
System > Loading Plate to Drum >
Solenoids/Valves > Cassette Inside Air Valve.
- In the Operation tab of the Cassette Inside Air
Valve dialog box, click Start.
- Allow the air to circulate for at least five minutes in order to
clear all accumulated moisture and dirt from the system, and
then click Stop.
- In the Cassette Inside Air Valve dialog box, select Cassette
Outside Air Valve from the Switch
drop-down menu and click Start.
- Allow the air to circulate for at least five minutes in order to
clear all accumulated moisture and dirt from the system, and
then click Stop.
- The air supply is purged. Close all dialog boxes.
Popups / Tool Tips for this Page