Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Procedure
1. Perform loading plate stage (a) with step by step.
2. When the question “operate open head gripper actuator”
appears on the PC screen,
Yes/No choose Yes.
3. Disconnect the X motor.
4. Choose "Abort" [to continue] for all the questions that
follow on the PC screen.
Note: The Loading bar is still holding the plate.
5. Push the loading system all the way to the drum
- Verify that the plate is positioned
underneath the head spoilers
- Pull the plate a little bit out but make sure that the plate is still under the spoilers.
6. From the loading gripper actuator motor turn off the gripper
Note: Only the head gripper catches the plate.
Check the Spiral Punch Position
Spin the drum by the head and see if the spiral pin that on the drum is in the center of the spiral punch notch.
If it isn’t, adjust the spiral punch position.