Lotem 800 automatic BIOS diskette for Windows 95

If required, there are two BIOS diskettes for the Lotem 800.
The only difference between the two versions, is the value of IRQ10, which can be either set as CI/PnP or as ISA/EISA, depending on the BIOS used:

Unsure how to make a BIOS diskette? More...

1. Download one of the Lotem BIOS diskettes to your desktop folder.
2. Insert a diskette into your diskette drive.
3. Double click on the BIOS icon that appears on your desktop (for example - Bios_V1.1.exe icon) and press Enter.

To amend the BIOS:

  1. Switch on the Lotem and press on the DELETE key until getting to the SETUP screen.
  2. Under the SETUP window use the arrow to select the UTILITIES and press <Enter>.
  3. Use the arrows to move to Secure CMOS and change to Disable (by using the <Enter> and arrows)
  4. Press ESCAPE twice and select "Save changes and Exit".
  5. Insert the Diskette to Drive a: and restart the PC.
  6. The Bios will load automatically to the CPU. When finished remove the diskette from Drive a: and restart the PC (by using ALT+CTR+DEL).
  7. During the start up you will need to go to the Setup again (by choosing "F1"). Select the UTILITIES and Secure CMOS (like the first time) and change the setting to ACTIVATED.
  8. Press ESCAPE twice and select Save changes and Exit.
    The Windows 95 will restart.
  9. Set the correct Date and Time.