Here are some updates of the release notes, they will also be added to the original release notes in the TIC:
Drum System/Balance System/Right Balance Arm Solenoid/On Current (1700)
= 1700
/Hold Current (840) = 840
/Left Balance Arm Detector/ On Current (1700) = 1700
/Hold Current (840) = 840
Problem: After moving the XY system manually from within the cassette,
machine would not perform "Init XY" and actually cannot
recover and identify the loading system location.
Workaround: Move the loading system manually back to its original location
inside the cassette (+/- 10 mm) and perform "Init XY".
If that does not work please restart the application.