Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Description
When loading Lotem™ PC version 3.61.00, the message: "unable to convert data base files" appears on the monitor. When accessing the GUI for the first time, the message: "illegal parameters read from grid file - write and reload a default grid?" appears on the monitor. In addition, when running diagnostics on version 3.61.00, the diagnostic test tree does not appear on the monitor.
To ensure your machine produces the desired results, make sure the following software parameters are set, as follows:
| Parameter | Value |
| punch motor det # 3 open | 0 |
| punch motor #3 open | 0 |
| punch spiral motor enable | 0 |
| punch sys/punch spiral unit | none |
| loading sys/from punch to drum/y up after centering | 74 |
| set up/unload arm for gto installed | 1 |
| exp/plate edge det enable | 1 |
| mcf cards/latch det/plate edge det/open | 1 |
| nuc cards/plate edge det hw/open | 1 |
| machine/max media thick | 0.3 |
| machine/min media thick | 0.2 |
| machine/max resolution | 100 |
| machine/max media width size | 899 |
| machine/max media height size | 990 |
| machine/min media height size | 457 |
| media adv | edge |
Note: All diagnostic tests performed under Drum fail.