Software Version 3.61.00 on Lotem 800 S Forms

Itai Peperovich
16-Jan-03

Description

When loading Lotem™ PC version 3.61.00, the message: "unable to convert data base files" appears on the monitor. When accessing the GUI for the first time, the message: "illegal parameters read from grid file - write and reload a default grid?" appears on the monitor. In addition, when running diagnostics on version 3.61.00, the diagnostic test tree does not appear on the monitor.

To ensure your machine produces the desired results, make sure the following software parameters are set, as follows:

  1. Change the unload detector from 29 to 30.
  2. Ensure the top margin is between 6 and 10, and the tolerance for the unload motor is between 3 and 15.
  3. Check the Registry parameter values on the Lotem 800 S Forms (edge detection without punch spiral). The following values should be configured:
    Parameter Value
    punch motor det # 3 open 0
    punch motor #3 open 0
    punch spiral motor enable 0
    punch sys/punch spiral unit none
    loading sys/from punch to drum/y up after centering 74
    set up/unload arm for gto installed 1
    exp/plate edge det enable 1
    mcf cards/latch det/plate edge det/open 1
    nuc cards/plate edge det hw/open 1
    machine/max media thick 0.3
    machine/min media thick 0.2
    machine/max resolution 100
    machine/max media width size 899
    machine/max media height size 990
    machine/min media height size 457
    media adv edge

Note: All diagnostic tests performed under Drum fail.