Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


New Interlocks (Omron)

New Interlocks operation

All doors (upper and side doors) and the upper rear panel have Omron interlock switches that disable the laser source and the motors.
The upper doors have two interlock switches each. The side doors have one interlock switch each. The upper and lower rear panels also have only one interlock switch each.
In order not to rely on the reliability of a single switch, the service engineer is required to keep one of the upper doors open if a side door or a rear panel is open.

Interlock Functions and Locations

Interlock
Location

Interlock
Function

Description of interlock Switches

Serviceman only Defeat Allowances

Upper rear door

(unloading)

Disable Lasers and Motors

2 interlock switches

1 defeat switch

Defeat switch only - to operate motors

Upper front door

(loading)

Disable Lasers and Motors

2 interlock switches

None

Upper rear panel

Disable Lasers and Motors

1 interlock switch

None

Lower rear panel

Disable Lasers and Motors

1 interlock switch

None

Left door

Disable motors only

1 interlock switch

Interlock magnetic switch - to operate motors

Right door

Disable lasers and motors

1 interlock switch

None

Cassette inlet opening

Disable motors only

1 interlock magnetic switch

 

Right side

Disable paper disposal motor only

1 interlock switch at each paper door

Interlock switch - to operate paper disposal motor


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.