All doors (upper and side doors) and the upper rear panel have Omron interlock
switches that disable the laser source and the motors.
The upper doors have two interlock switches each. The side doors have one interlock
switch each. The upper and lower rear panels also have only one interlock switch
each.
In order not to rely on the reliability of a single switch, the service engineer
is required to keep one of the upper doors open if a side door or a rear panel
is open.
|
Interlock |
Interlock |
Description of interlock Switches |
Serviceman only Defeat Allowances |
|
Upper rear door (unloading) |
Disable Lasers and Motors |
2 interlock switches 1 defeat switch |
Defeat switch only - to operate motors |
|
Upper front door (loading) |
Disable Lasers and Motors |
2 interlock switches |
None |
|
Upper rear panel |
Disable Lasers and Motors |
1 interlock switch |
None |
|
Lower rear panel |
Disable Lasers and Motors |
1 interlock switch |
None |
|
Left door |
Disable motors only |
1 interlock switch |
Interlock magnetic switch - to operate motors |
|
Right door |
Disable lasers and motors |
1 interlock switch |
None |
|
Cassette inlet opening |
Disable motors only |
1 interlock magnetic switch |
|
|
Right side |
Disable paper disposal motor only |
1 interlock switch at each paper door |
Interlock switch - to operate paper disposal motor |