Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Description
A recent report from the production line states that a machine in a very advanced
stage was suddenly having "laser power supply fail" problems during
exposing. A large group of diodes failed to make calibration. To recover from
this problem, a complete start up was required.
The start up helps sometimes, but the problem returned.
Cause
After investigation, we discovered that the nuts on the cables from the (-5 V) power supply to the main M.B were not tightened securely inside the L-box. Due to the loose nuts, the -5 V did not reach the M.B therefore causing this failure.
We are uncertain if any other L-boxes with the same problem had left CSIL. Therefore, when facing the same symptoms, please check the -5 V nuts on the power supply cables from both sides (please see the pictures below).
Checking the cable connections on the power supply side
Checking the cables connections on the M.B. side.