Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Preventing the Lotem 800 (Local2) drum from shutting down during an exposure


Product

  Only applies to Lotem® 800 platesetters fitted with a Local2 board.

Operating system

 

Lotem Controller version 3.61.02


Error

  The following error messages are associated with this problem:
  • Drum go position task timeout
  • Drum go speed task timeout

Symptoms

 
  • Power ceases to be fed to the drum, causing it to shut down while a plate is being exposed.
  • A 5230 error message is displayed on the Brisque.
  • A drum vibration error message is occasionally displayed.

Cause

 
  • Voltage from MCF board is too low.
  • Punch board has coating problems.

Solution

 
  • Readjust the MCF board's voltage to 5.1 volts
  • Replace the punch board.

Technical contact(s)
 

Moshe Arviv

Submitted by
 

Moshe Arviv

Date submitted
 

19 Jan 2004