Product

 
  • Lotem® 800 FH Family
  • Lotem 800 II Family
  • Lotem 800 Quantum
  • Lotem XL
  • Lotem 400 FH Family
  • Lotem 400 Quantum
  • Lotem ThermoFlex® Mid/Narrow

  • Symptoms

     

    The platesetter is locked in a permanent state of shut down.


    Cause

     

    This problem occurs when:

    • FCO #512-01500 Power Failure Protector Board has been implemented,

      AND

    • Platesetter is not shut down according to the following recommended procedure:
      • Shut Down via Lotem Controller
      • Pressing the yellow On/Off button
      • Turn off the main circuit breaker in the D-box

    Solution

     
    1. Remove the rear lower panel.
    2. Remove the rear trapeze.
    3. Remove FCO 512-01500 from the distribution box.
    4. Reconnect the platesetter's main harness directly to the distribution box - as it was in the previous configuration before the FCO was implemented.
    5. Replace the rear lower panel and trapeze
    6. Restart the platesetter.