Resolving the 'Protector XY punch is locked by X motor' error message


Product

 

Lotem® 800


Error

 

Protector XY punch is locked by X motor


Symptoms

 

The error message is associated with the following symptoms:

  • XY bar does not move
  • Bar flag is stuck in the up position

Cause

 

The wires inside the XY bar may be preventing the bar flag from returning to its down position. If the flag is stuck in the up position, the system interprets this to signify that the XY bar is lowered and hence an error message is generated.


Solution

 

In Lotem Controller, check the status of the bar flag.

If the bar flag is ON, do the following:

  1. Remove the XY bar cover.
  2. Check why the bar flag cannot return to its down position.
    If required, rearrange the wires inside the XY bar, so that they are not obstructing the bar flag:



  3. Ensure that the bar flag can move freely.
  4. Replace the XY bar cover.

Technical contact(s)
 

Itai Peperovich

Submitted by
 

Itai Peperovich

Date submitted
 

01 Oct 2003