Saving and Restoring NVS Parameters

Command Result

C:\Th2\Tools\
bload f=File name_ram.bin p=X b=57600 d=ram I=nvs upload

To save the NVS parameters from the MCE to the diskette.
Note: The file must be saved in the same folder as the bload program.
C:\Th2\Tools\
bload f=file name_flash.bin p=X b=57600 d=flash I=nvs upload
To save the Flash from the MCE to the disk
Note: The file must be saved in the same folder as the bload program.
C:\Th2\Tools\
bload f=file name_ram.bin p=X b=57600 d=ram I=nvs
To Restore the NVS parameters to the MCE.
Note: The file must have been created using the version of firmware that is being loaded.
C:\Th2\Tools\
bload f=file name_flash.bin p=X b=57600 d=flash I=nvs
To Restore the flash to the MCE.
Note: The file must have been created using the version of firmware that is being loaded.
Quantum>> nvs dump diff
Backing up NVS to ASCII text file:
All NVS parameters which are not at their default value will be saved to a text file.
Type this command at the monitor (procomm) and use your terminal to capture data from the screen.


Note:
X
represents the com port in use.
In case the loading / saving failed, delete the file that was already created and re-save.
In case the loading / saving failed repeatedly, reduce the baud rate at the procoom application.
Type Quantum>> MCE baud 9600
Change the procomm monitor baud rate to 9600.
At the end of the loading return the baud rate to 57600.
f represents the filename.

 