Field Change Order #512-00470 carriage amplifier board replacement

Applies to

 
  • Lotem® 800 Quantum
  • Lotem 850 Quantum
  • Lotem Spectrum Quantum
  • Lotem 800 II Family
  • Lotem 400 Quantum

Priority = Next visit
Release date = 25 Feb 2003

Component

 

Carriage amplifier board.

Problem

 
  • Connectors J1 and J3 do not meet electric current requirements.
  • Intermittent error  Carriage Amplifier did not detect occurs due to noise on the carriage amplifier board.

Solution

 

Improve the power supply to the carriage amplifier board by replacing both the J1 and J3 connectors:

The board, which receives 48V directly from the TMC, generates +/- 12V and 5V. Since the new board includes new J1 and J3 connectors, you need to replace the following two cables:

  • The cable between the carriage amplifier board and the carriage motor.
  • The power supply cable between the TMC and the carriage amplifier board.

Note: This FCO has already been implemented in platesetters leaving the production line after 4/3/2003, with serial number 131029.

Time needed to implement

 

1 hour

Parts needed

 

Part Name

Qty

Part Number

Carriage amplifier board

1

503C01525B
Carriage AM power cable 1 504L4E388
E-wiring + cable 1 504L4E389
FCO document, carriage amplifier replacement 1 719-00470

Procedure

 
  1. Shut down the Lotem.
  2. Unplug the connectors on the carriage amplifier board, then remove the carriage amplifier board.
  3. Make sure to remove the protective liner from the carriage driver heat sink compound:


Note: The protective liner is a transparent nylon sheet covering the purple cloth liner. Remove only the protective transparent liner.

  1. Assemble the new carriage amplifier board.
  2. Replace the existing carriage amplifier power cable with the new power cable (P/N 504L4E388).
  3. Replace the existing carriage motor cable with the new motor cable (P/N 504L4E389) by running it along the main upper harness:
  1. Reconnect the J1 and J3 connectors:

  1. Run a customer's job to check that the Lotem operates properly.

Logistics

 

Approved quantities: 

CSC

Quantity

CAM:

40

CEU:

70

CAP:

15

CJP:

15

CMA:

5
CCA:  

Other:

 

No Limit:

 

Schedule supplies for first lots: 

CSC

Month

Qty

Month

Qty

Month

Qty

CAM:

Feb 5 Mar 30 Apr 5

CEU:

Feb 5 Mar 45 Apr 20

CAP:

Feb 5 Mar 10    

CJP:

Feb 5 Mar 10    

CMA:

    Mar 5    
CCA:            

Other:

           

 

Material Disposition

 

Throw away the old carriage amplifier board.


Technical contact
 

Nir Peleg

Date submitted
  25 Feb 2003

719-00470
Revision B