Applies to |
|
- Lotem® 800 Quantum
- Lotem 850 Quantum
- Lotem Spectrum Quantum
- Lotem 800 II Family
- Lotem 400 Quantum
|
Priority = Next visit
Release date = 25 Feb 2003
|
Component |
|
Carriage amplifier board.
|
Problem |
|
-
Connectors J1 and J3 do not meet electric current requirements.
- Intermittent error
Carriage Amplifier did not detect
occurs due to noise on the carriage amplifier board.
|
Solution |
|
Improve the power supply to the carriage amplifier board by replacing
both the J1 and J3 connectors:

The board, which receives 48V directly from the TMC, generates +/- 12V
and 5V. Since the new board includes new J1 and J3 connectors, you need
to replace the following two cables:
- The cable between the carriage amplifier board and the carriage motor.
- The power supply cable between the TMC and the carriage amplifier
board.
Note: This FCO has already been implemented in platesetters
leaving the production line after 4/3/2003, with serial number 131029.
|
Time needed to
implement |
|
1 hour |
Parts needed |
|
|
Part Name
|
Qty |
Part Number
|
Carriage amplifier board |
1 |
503C01525B |
| Carriage AM power cable |
1 |
504L4E388 |
| E-wiring + cable |
1 |
504L4E389 |
| FCO document, carriage amplifier replacement |
1 |
719-00470 |
|
Procedure |
|
- Shut down the Lotem.
- Unplug the connectors on the carriage amplifier board, then remove
the carriage amplifier board.
- Make sure to remove the protective liner from the carriage driver
heat sink compound:
Note: The protective liner is a transparent nylon sheet covering
the purple cloth liner. Remove only the protective transparent liner.
- Assemble the new carriage amplifier board.
- Replace the existing carriage amplifier power cable with the new
power cable (P/N 504L4E388).
- Replace the existing carriage motor cable with the new motor cable
(P/N 504L4E389) by running it along the main upper harness:
- Reconnect the J1 and J3 connectors:

- Run a customer's job to check that the
Lotem operates properly.
|
Logistics |
|
Approved quantities:
CSC |
Quantity
|
CAM: |
40 |
CEU: |
70 |
CAP: |
15 |
CJP: |
15 |
CMA: |
5 |
| CCA: |
|
Other: |
|
No Limit: |
|
Schedule supplies for first lots:
|
CSC
|
Month |
Qty |
Month |
Qty |
Month |
Qty |
CAM: |
Feb |
5 |
Mar |
30 |
Apr |
5 |
CEU: |
Feb |
5 |
Mar |
45 |
Apr |
20 |
CAP: |
Feb |
5 |
Mar |
10 |
|
|
CJP: |
Feb |
5 |
Mar |
10 |
|
|
CMA: |
|
|
Mar |
5 |
|
|
| CCA: |
|
|
|
|
|
|
Other: |
|
|
|
|
|
|
|
Material Disposition |
|
Throw away the old carriage amplifier board.
|
|
Technical
contact |
|
Nir Peleg
|
Date submitted |
|
25 Feb 2003 |