FCO #512-03285A - Resolving 'Local3 does not respond' error message

Applies to

 
  • Lotem® 800
  • Lotem 800 II
  • Lotem 800 Quantum
  • Lotem 850
  • Lotem Quantum Spectrum
  • Lotem Spectrum
  • ThermoFlex Mid/Narrow
  • Lotem Quantum 400
  • Lotem 400
  • Lotem Xpose
Priority: Next failure
Release date: 01 Feb 04

Component

  Local3 box assembly.

Problem

  The error message Local3 board does not respond is generated because the board resets itself due to electrostatic discharges.

Solution

  The problem is solved by adding a capacitor to the new Local3 board's reset circuit.

Note:
The new Local3 board (p/n 506D2D462C) includes the previous FCO carried out on the Local3 board:
FCO 512-02139 Preventing Local3 board error messages

Time needed to implement

  30 minutes.

Parts needed

 
Part name Quantity Part number
RSC box L170x380x170 1 391S60606
Local3 box assembly 1

506D2D462C

FCO 512-03285A document 1 719-03285A Rev A

 

Important: Each FCO kit contains one Local3 box assembly. Use the table below to determine how many kits you will require:

Model No. of Local3 boards required
  • Lotem Quantum 400
  • Lotem 400
  • Lotem Xpose
Without MCU 1
With MCU 2
  • Lotem 800 Fiber Head Family
  • Lotem 800 II Family
  • Lotem Quantum Family
  • Lotem Quantum 850 II Family
Without MCU 2
With MCU 3
  • Lotem ThermoFlex
2

 

Procedure

 
  1. From within Lotem Controller, open the front door of the platesetter.
  2. Open the left and right hand doors.
  3. Quit Lotem Controller and shut down the platesetter.
  4. Remove the Local3 boards from the platesetter.
  5. Install the new Local3 boards (p/n 506D2D462C).
  6. Turn on the platesetter and start Lotem Controller. The interlock message is displayed.
  7. Close all the doors and ensure that the platesetter is in Ready mode.
    Note: If the platesetter's status is Offline do the following: From Lotem Controller, click the On line button, located under the Routine Functions menu.

Logistics

  Approved quantities:

CSC Quantities
Jan 04 Feb 04 Mar 04
CAM: 7 7 7
CEU: 20 20 20
CAP: 5 5  
CJP: 15 15 15

Inventory: Replace Local3 board with a new Local3 board (p/n 506D2D462C).
Lead time: Please instruct CSCs to order the FCO. For additioanl FCOs, the lead time is approximately one month.

Material disposition

  Return the old Local3 box assembly to CIL for ECO refurbishing.

Document number
  719-03285A Rev A
Technical contact(s)
  Itai Peperovich
Product Support Manager: Yaron Soffer
Approval Date: 01 Feb 04