Field Change Order #28852—Proof unloading arm EP/HP detector bracket for Lotem 800 with Spectrum


Applies to

 
  • Lotem™ 800 Spectrum
  • Lotem 800 Quantum Spectrum

Release date = 16 Jun 2002
Type of change = Mandatory

Machines affected

 

All Lotem 800 Spectrum machines that have PC controller software version 3.50.06 or later installed.

Component

  EP/HP detector bracket

Problem

 

In PC controller software version 3.50.06 and later, changes have been made to improve synchronization between the movement of the drum and the proof unloading arm during the unloading sequence. To complement these changes, the unloading arm EP (end position) and HP (home position) detectors need to be repositioned.

Solution

 

Installation of a slightly larger unloading arm EP/HP detector bracket (P/N 290A2S563A). After the bracket is installed, the EP/HP flag must be adjusted.

Time needed to implement

 

1 hour

Parts needed

 

FCO Kit No: 510F28852

Part name Qty P/N
SENSOR DOUBLE BRACKET 1 290A2S563A
JIG I FOR UNLOAD SPECTRUM 2 291A9B288
JIG 2 FOR UNLOAD SPECTRUM 2 291A9B289
PACKING LABEL-WHT 1 374A00080
FCO DOCUMENT 1 719-28852 REV. A

Procedure

 

This procedure includes the following steps:

  1. Installing the EP/HP detector bracket
  2. Adjusting the EP/HP detector flag
  3. Testing functionality

Installing the EP/HP detector bracket

  1. Open the rear door of the Lotem.
  2. Unplug the EP and HP detector connectors (shown below).
  3. Remove the two Allen™ screws that secure the detector bracket to the unloading bar assembly and remove the bracket from the machine.
  4. Remove the Allen screw that secures the HP detector to the bracket, and remove the Allen screw that secures the EP to the bracket.
  5. Secure the EP and the HP detectors to the larger bracket (P/N 290A2S563A) using the two screws that you removed in step 4.
  6. Secure the larger bracket to the unloading bar assembly using the two screws removed in step 3.
  7. Connect the EP detector connector to the EP detector ,and connect the HP detector connector to the HP detector.
    Note: The HP detector is the lower one.

Adjusting the EP/HP detector flag

  1. Leave the rear door open and load the carrier onto the drum (use cheaters, as required).
  2. Verify that the proof unloading arm is in HP.
  3. Place one of the 3 mm jigs on the far right of the unloading arm, as follows:
    1. Position the jig over the far right (toward the end) of the proof unloading arm as shown in the picture below.
      Note: Ensure that the jig is positioned far enough toward the end of the proof unloading arm that it does not cover any suction cups.
    2. Move the jig downward so that the lip fits onto the proof unloading arm.
    3. Slide the jig toward the center of the machine until it covers the outermost suction cups.
      Note: Ensure that the outermost suction cup (the first one) is completely covered by the jig, as shown below.
  4. Place the other 3 mm jig on the far left of the proof unloading arm, as described in step 3.
  5. In the PC controller, activate the proof unloading valve. The proof unloading arm moves upward to the end position (EP).
  6. In the PC controller, access the following dialog boxes:
  7. Loosen the two EP/HP flag setscrews on the flag unit (shown below).
  8. Manually rotate the flag unit until the status of the Proof Unloading End Pos Detector toggles to ON.
  9. Manually rotate the flag unit until the status of the Proof Unloading End Pos Detector toggles to OFF. The moment it toggles to OFF, hold the flag unit still and tighten the two EP/HP flag setscrews.
  10. Deactivate the proof unloading valve. The proof unloading arm moves downward to the HP.
    Note: The status of the Proof Unloading Home Pos Detector should be ON.
  11. Remove the two 3 mm jigs from the proof unloading arm.
  12. Place the two 1 mm jigs on the unloading arm as described in steps 3 and 4.
  13. Activate the proof unloading valve. The proof unloading arm moves to the EP, and the Proof Unloading End Pos Detector status should toggle to ON. If it does not, put the 3 mm jig back on the unloading arm, return to step 7 and repeat the process.
  14. Deactivate the proof unloading valve and remove the jigs.
  15. Activate and deactivate the proof unloading valve three or more times and verify that:
    • When the valve is activated, the proof unloading arm is in the EP, and:
      • The status of the HP detector is OFF.
      • The status of the EP detector is ON.
    • When the valve is deactivated, the proof unloading arm is in the HP, and:
      • the status of the HP detector is ON
      • the status of the EP detector is OFF

Testing functionality

  1. Leave the rear door open and, using cheaters, load a carrier and a receiver.
  2. Load and unload a donor. Repeat this step several times and verify that the unloading sequence is smooth and correct.
    • If the following error message appears, repeat the entire adjustment process, as described in Adjusting the EP/HP detector flag, and test functionality again:
      • "The proof unloading arm end position detector still stayed at ON state X milliseconds after the arm was retracted".
    • If the error message appears again, change the value for the 'Time To Wait For Proof Unload Arm EP Detector (mSec)' parameter (default=500), as follows:
      • Increase the current value by 100, and repeat the test procedure.
      • If the error message appears again, increase the current value again by 100, and repeat the test procedure.
      • Continue increasing the value by 100 until the unloading sequence can be completed without the error message appearing.
        Note: The maximum allowable value for this parameter is 1000. Do not enter a value of more than 1000.
  3. Remove all cheaters and close all doors.

Logistics

 

Approved quantities:

DU QTY
CAM: 12
CEU: 3
CAP: 1
CJP:  
CMA:  
Other:  
No Limit:  

Schedule supplies for first lots:

DU Month Qty Month Qty Month Qty
CAM: August 12        
CEU: August 3        
CAP: August 1        
CJP:            
CMA:            
Other:            

Lead Time: 1.5 months

Material Disposition

  Throw the removed bracket away.

Technical contact
 

Nir Peleg

 

Project Manager: Jerry David  

Approval:

Date submitted
  16 Jul 2002


Popups / Tool Tips for this Page

   Close this popup...   To activate/deactivate the proof unloading valve:

  1. In the PC controller, select Utilities > Hardware.
  2. In the displayed Hardware tree, double-click Unloading system > Solenoids/Valves > Proof Unloading Valve. The Proof Unloading Valve dialog box is displayed.
  3. In the Operation tab of the Proof Unloading Valve dialog box, click Start. The proof unloading valve is activated, and the proof unloading arm moves to HP.
  4. In the Operation tab of the Proof Unloading Valve dialog box, click Stop. The proof unloading valve is deactivated, and the proof unloading arm moves to EP.

   Close this popup...   To access the Proof Unloading End Pos Detector dialog box:

  1. In the PC controller, select Utilities > Hardware.
  2. In the displayed Hardware tree, double-click Unloading system > Detectors > Proof Unloading End Pos Detector. The Proof Unloading End Pos Detector dialog box is displayed.

   Close this popup...   To access the Proof Unloading Home Pos Detector dialog box:

  1. In the PC controller, select Utilities > Hardware.
  2. In the displayed Hardware tree, double-click Unloading system > Detectors > Proof Unloading Home Pos Detector. The Proof Unloading Home Pos Detector dialog box is displayed.

   Close this popup...   To increase the value by 100, add 100 to the current value. For example, if the value is currently set at 600, type 700. The value is increased by 100.

   Close this popup...   EP/HP detector securing screws

   Close this popup...   The picture below shows the 3 mm and 1 mm jigs. Note that the 3 mm jig is the one with the additional piece on the bottom.

   Close this popup...   Slide the jig toward the end of the proof unloading arm until it no longer covers any suction cups. Then, press the jig upward and take it off of the bar.

To access the 'Time To Wait For Proof Unload Arm EP Detector (mSec)' parameter:

  1. In the PC controller, select Utilities > Hardware.
  2. In the displayed Hardware tree, double-click Loading System > Unload Proof and then right-click Delays.
  3. Scroll to display the 'Time To Wait For Proof Unload Arm EP Detector (mSec)' parameter, as required.