Type II Mainframe (Chassis)

An improved mainframe or chassis has been developed for the platesetter. This latest mainframe, referred to as the Type II mainframe, is more functional than its predecessor (Type I mainframe) and contains greater service access.

Note: To visibly distinguish between the two types of mainframe, see Distinguishing between Type I and Type II mainframes.

This page describes the improvements made on the Type II mainframe:

Right Side Door

Part
Photos
Improvement
E-Box
New SBC 786 board.
Keyboard/mouse Y splitter cable
(p/n 609-00281)
Only one keyboard extension cable (p/n: 199D20220) is connected to the 800 II accessory kit. Connect one end of the cable to the SBC and the other end to the Y splitter cable.
TMCE Board
Moved to the right door to allow better service and replacement access. A screw from the Type II mainframe's body closes the TMCE door.
Note: After you open/close the TMCE door, make sure that all the wiring is in place to avoid circuit shorting and damages.
CA Board
Moved to the right door to allow better service and replacement access. The CA board is the smaller board above the TMCE board.
Power Fail Protector Board Assembly
When power surges occur, the power fail protector board assembly maintains the platesetter in OFF status until the On/Off pushbutton is toggled.

 

Left Side Door:

Part
Photos
Improvement
Power Supply Tray
 
Removed, and relocated inside the distribution box.
Left Local Board
Moved from the left side door upper compartment to the lower one, instead of the power supply.
Cooling Filter 24x12
Better service and replacement access. The filter is held by two pull-out latches, which are activated by the customer.

 

Rear:

Part
Photos
Improvement
Drum Vacuum Pump
Moved to the place of the cooling system.
Debris Vacuum Hose
Moved towards the left side door.
Note: This change also required a change at the distribution panel and therefore, a new part number.
Loading Vacuum Pump
Replaced with a vacuum generator unit located above the drum vacuum pump.

 