Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Description
Unique to the Lotem Spectrum, the proofing media is held to the drum with
vacuum alone (and without grippers). The Drum Vacuum Analog Detector,
also unique to Spectrum machines, measures the vacuum pressure on the drum during
loading with the Carrier, with the Receiver and with the Donor. It is important
to set the correct value to prevent the media from flying off during exposure.
![]() |
Loading the Carrier
The Carrier loading sequence is similar to the plate loading sequence.
When the Carrier is wrapped on the drum, the Drum Vacuum Pressure
should be in the range of ~-250 - -470.
Proofing Media - Receiver & Donor
The proofing media - Receiver and Donor - are loaded on top of the Carrier
and are held by vacuum only. You must set a minimum Drum Vacuum Value prior
to loading the media, and during exposure.
|
Lotem 800 Spectrum Beta 4 and Lotem 800 Quantum
Spectrum 3.50.07
Drum Vacuum Pressure Checks for Proof Media |
|||
|
|
When to check |
What to check |
Duration of check |
|
Loading |
|||
|
Carrier |
1.When Carrier is completely wrapped on drum 2.When Receiver is attached to Proof Loading Bar |
Value is within the drum vacuum
pressure range defined in the registry for Carrier on drum. |
1.Maximum 30 seconds, polling every (1) second 2.One second |
|
Receiver |
When Donor is attached to Proof
Loading Bar |
Value is equal to or greater than the minimum
Drum Vacuum Pressure defined in the registry for Receiver on drum. |
One second |
|
Donor |
When Donor is completely wrapped
on drum |
Value is equal to or greater than the minimum
Drum Vacuum Pressure defined in the registry for Donor on drum. |
Maximum 30 seconds, polling every
(1) second |
|
Unloading |
|||
|
Receiver |
1.Before detaching receiver with the Proof Unload Arm from the drum 2.After shutting off drum vacuum |
Value is below the maximum Drum
Vacuum Pressure defined in the registry for receiver unload |
Maximum 30 seconds, polling every
(1) second |