Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Resolving Lotem 800 II configuration issues when upgrading to Lotem 800 Controller software version 3.75.09


Product

 

Kodak® Lotem® 800 II platesetters

Operating system

 

Lotem 800 Controller software version 3.75.09


Error

 

Station platform does not allow to configure a new device of selected type.


Symptoms

 

If the CFL FCO has been implemented on a Lotem 800 II platesetter, and you then attempt to upgrade the Lotem 800 Controller software from version 3.75.01 to software version 3.75.09, the Station platform.. error message is generated and the upgrade fails.


Solution

 
  • Verify that the dongle is installed correctly
  • Perform a cold start
  • Replace the Brisque's CPU

Technical contact(s)
 

Alon Davidor

Submitted by
 

Alon Davidor

Date submitted
 

13 May 2007