Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Preventing passes when exposing mixed (Staccato/AM) files


Product

 
  • Lotem® 800 Quantum
  • Lotem 800 II
  • Lotem Quantum Spectrum
  • Lotem 400 Quantum

Symptoms

 

When a mixed Staccato® / AM file is exposed onto a positive plate, a 10 micron black line appears along the join where the two different exposure types meet.


Cause

 

When exposing a mixed file, the carriage has to make more than one pass. On the second pass, a 10 micron black line will appear. This line is caused by a blind spot located along the join where the two exposure types meet.


Solution

 

A patch will be implemented in the next Brisque® update. The new patch will reduce the appearance of the lines by reducing the number of passes. For example, two different Staccato screens on the same job will be exposed in one pass as opposed to two passes.


Technical contact
 

Nir Peleg

Submitted by
 

Nir Peleg

Date submitted
 

06 Aug 2003