Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Symptoms |
After replacing a cassette on the Lotem platesetter, the first job for the new media generates the following two warning messages:
|
||
Cause |
In Brisque version 3, to update the plate status, a small configuration adjustment had to be performed prior to exposure. In Brisque versions 4.1 and 5, the performance was improved, but after adding plates and updating the number in the PC Controller, it was still necessary to reconfigure the Brisque again. |
||
Solution |
Reconfigure the Brisque after you replace a cassette. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
30 May 2003 |
||