Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Preventing the “Missing Object None” error message on Lotem 800 platesetters


Product

 
  • Kodak Lotem 800
  • Kodak Lotem 800 II
  • Kodak Lotem 850

Error

 
  • Missing Object None
  • Operation not successful

Symptoms

 

When changes are made to the registry, a Missing Object None error message appears in Kodak Lotem Controller.

In addition, Lotem Controller may freeze during start-up, and/or an Operation not successful error message may appear.


Cause

 

The error message is generated when registry changes are entered in lowercase letters (a, b, c) instead of uppercase letters (A, B, C).


Solution

 

Ensure that registry changes are entered in uppercase letters, as shown below:

“Home Pos Detector”=“NONE”

“Home Pos Detector”=“none”


Technical contact(s)
 

Alon Davidor

Submitted by
 

Alon Davidor

Date submitted
 

10 Aug 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.