Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Exposing half resolution option on Lotem Quantum


Product

 
  • Lotem® 800 Quantum
  • Lotem 850 Quantum
  • Lotem 400 Quantum
  • Lotem Quantum Spectrum
  • Lotem 800 II

Error

 

"Cannot plot at resolution requested. Allowed range is 94 ..... to 100."


Symptoms

 

When trying to expose the half resolution option, the above error message is displayed.


Cause

 

The expose resolution 1270 dpi or 1200 dpi option is supported by PC versions 3.6 and 3.70.02, but not by version 3.51.02.


Solution

 

To expose the half resolution option:

  1. From Splot, enter the set duplicate command, as follows: Quantum>>Set mode 2 SscanDuplicate 2
    Note: This command is for the sub scan resolution only.
  2. The output is as follows:
Group Parameter Active Default Units
mode MscanResolution[2] 1270 2400 DPI
mode SscanResolution[2] 1270 2400 DPI
mode MscanDuplicate[2] 1 1  
mode SscanDuplicate[2] 2 1  

Note: When working with Xilinx version 1.38 or higher, the MscanDuplicate should also be changed to 2, as shown in the following example:

mode MscanDuplicate[2] 2 1
mode SscanDuplicate[2] 2 1

Technical contact(s)
 

Nir Peleg

Submitted by
 

Nir Peleg

Date submitted
 

19 Dec 2002


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.