Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
|||||||||||||||||||||||||||
Component |
MCE |
|||||||||||||||||||||||||||
Symptoms |
When working with MCE version 1.26 or higher, the command syntax to head must be entered differently. |
|||||||||||||||||||||||||||
Cause |
The syntax for accessing Thermal 2 head parameters on MCE-based machines has been changed. The syntax of these parameters has been significantly changed and is accessible only through redirection, and not through "set head," "set hdp," or "set hdm." This syntax enables the head parameters to be changed without having to release a new version of firmware for each host. It also allows a single host to connect to different heads without having to know the parameter details of each head. |
|||||||||||||||||||||||||||
Solution |
The Thermal 2 head NVS parameters are no longer mapped to MCE NVS and should only be accessed through the Thermal 2 head redirection. The table below includes examples of both the former syntax and the revised syntax for accessing the Thermal 2 head parameters. Note the changes in the syntax:
Note: The revised syntax can be used with all existing firmware.
|
|||||||||||||||||||||||||||
Technical contact(s) |
||||||||||||||||||||||||||||
Submitted by |
||||||||||||||||||||||||||||
Date submitted |
07 Nov 2002 |
|||||||||||||||||||||||||||