Solution |
|
Determine whether the problem is related to upstream data (Prinergy
to platesetter) or downstream data (platesetter to TH2 head).
- Create a test file.
- Expose the file, and ensure that lines do not appear on the image.
- Save the Service Shell log file that contains the test files
exposure data information.
- Locate and then copy the log files cycle redundancy check
(CRC) values.
- When lines appear on an image, expose the test file used in step 1
and perform the following actions:
- Ensure that lines appear on the exposed test file.
- Compare the CRC values for the exposure in which lines appear
with the CRC values for the exposure without lines.
If the CRC values are different for both exposures, the problem
can be isolated to upstream data (Prinergy to platesetter).
If the CRC values are the same for both exposures, then the problem
can be isolated to downstream data (platesetter to TH2 head).
Resolve upstream data problems
Individually perform each of the following steps and then, after each
step, check whether the problem has been resolved.
- On the Prinergy workstation, ensure that the latest version
of the SCSI driver board is installed. If required, upgrade the SCSI
driver to the latest version.
- Ensure that there is a sufficient distance between the Prinergy
SCSI cable and any high-voltage cables.
- Ensure the SCSI cables connector pins are not damaged. If there
is any damage to the pins, replace the SCSI cable.
- Replace the SCSI cable adapter.
- Replace the Prinergy workstations SCSI board.
- Ensure that the standard Prinergy workflow has been correctly
configured.
- Ensure that the Prinergy workstation has sufficient memory
installed.
- Replace the Prinergy workstation.
Resolve downstream data problems
Individually perform each of the following steps and then, after each
step, check whether the problem has been resolved.
- Ensure that the power entering the devices is correctly conditioned
and that the grounding meets the recommended Kodak prerequisites.
- Ensure that the latest versions of the TMCE board and the TH2 head
are installed. If required, upgrade the firmware.
- Replace the TMCE board.
- Replace the data cable located between the TMCE board and the TH2
head.
- Replace the power cable located between the TMCE board and the TH2
head.
- Replace the hot link cable located between the TMCE board and the
TH2 head.
- Replace the TMCE and TH2 power supply.
- Replace the distribution box.
- Replace the TH2 head.
|