Resolving right board error messages after installing Service Shell 2.6 SP2 onto a Lotem 800 II Family platesetter


Product

 

Kodak® Lotem® 800 II platesetter


Error

 

Right local board error messages are generated after installing Service Shell 2.6 SP2 onto the platesetter.


Symptoms

 
  • Some of the com. ports do not appear in the hardware tree
  • Right local board error messages are generated

Solution

 
  1. Verify that com. ports 1, 2, 3, and 4 appear in the hardware tree.
  2. Locate the Device Manager window. Under the Modem section, make sure there is no Communication cable between the two computers. If required, right-click Communications cable between two computers and select Uninstall. This enables com. 3 to communicate with the right local board and ensures Lotem 800 Controller loads without any further problems.

 


Technical contact(s)
 

Alon Davidor

Submitted by
 

Greg Banks

Date submitted
 

21 Mar 2007