Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Component |
Enable detector - Part number 138A10080 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Symptoms |
The enable detector (p/n 138A10080) does not always detect the drum. This problem can lead to loading failures and plate fly-off scenarios. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cause |
The operational range of the existing enable detector (p/n 138A10080) is too limited. Therefore the detector does not always recognize the position of the drum. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Solution |
Replace NOT ONLY the existing enable detector, but several other detectors with a newly enhanced detector. When a Service Engineer orders an assembly/kit from the table
below, CSC Logistics will automatically ship an enhanced detector
kit with the new assembly/kit. Before installing the new assembly/kit onto the Lotem, the Service Engineer
replaces the existing detector with one of the detectors from the enhanced
detector kit.
Notes:
The table below lists all the assemblies and additional kits that require replacement detectors:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Technical contact(s) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Submitted by |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Date submitted |
24 Nov 2003 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||