Field Change Order 27993 - power distribution board C.L.-N


Applies to

 
  • Lotem Thermoflex 4045
  • Lotem Thermoflex 4047

Priority = Next visit
Release date = Sep 2001
Type of change = Conditional

Component

 

Power distribution board
Comp Level = N

Problem

 

Capacitor burns out.

Solution

 

Power distribution board comp level was updated. The catalog number has changed, but the functionality remains unchanged.

Time needed to implement

  10 minutes

Parts needed

 

Catalog No: 503C2L605S
FCO Kit No: 510F27993

Part Name Qty P/N
FLX_PWR_Distribution Board ASSY 1 503C2L605S
FCO doc 1  

Procedure

  Replace the old power distribution boards in stock with new boards having comp level N.

Logistics

 

Lead Time: 1 month

Material Disposition

  Return old boards to CIL.