Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


“DDB returned illegal buffer length” message appears


Product

 
  • Kodak® ThermoFlex® Mid 4045 and 4048
  • ThermoFlex Narrow 2630

Error

 

DDB returned illegal buffer length


Symptoms

 

After installing the UDRC sensor and updating the ThermoFlex Controller software version, the error message appears.


Cause

 

The L-box hardware is not supported by the following versions of ThermoFlex Controller software:

  • Windows® 95 1.32.350.004 or higher
  • Windows XP 2.02.354.005 or higher

Solution

  Update the L-box, as described in step 14 on pages 7-10 in FCO 512-00425A.

Technical contact(s)
 

Viki Arviv

Submitted by
 

Lee Giuricich

Date submitted
 

16 Jun 2008


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.