“The get of 94.487999 from the res motor table failed...” error appears in ThermoFlex Controller


Product

 
  • Kodak® ThermoFlex® Mid
  • ThermoFlex Mid II
  • ThermoFlex Narrow

Error

 

The get of 94.487999 from the res motor table failed. This key is out of range.


Symptoms

 

When imaging a TIFF file or calibration test in resolution 2400/94.488, the subject error appears.


Solution

 

Perform one of the following solutions:

  • For resolution 2400, in the machine Data Base tables in both the Res Motor and Intensity areas, build two tables: one for 94.488190, and the second for 94.487991.
  • Load the software 2.03.355.003

Technical contact(s)
 

Viki Arviv

Submitted by
 

Viki Arviv