Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


"DDB Card Doesn't Respond (Opcode82) The operation of Put DDB Card Failed." error message appears on ThermoFlex Mid and Narrow


Product

 
  • ThermoFlex® Mid
  • ThermoFlex Narrow

Error

 

DDB Card Doesn't Respond (Opcode 82). The operation of Put DDB Card Failed.


Cause

 

The host tries to establish communication with the DDB board, but the action times out.


Solution

 

In the registry, select IO OBJECTS\DDB Cards\DDB Card and change the TimeOut For Embedded Communication [mSec] parameter value from 3000 to 5000.


Technical contact(s)
 

Viki Arviv

Submitted by
 

Frederic Mayot

Date submitted
 

21 May 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.