Symptoms |
The drum and focus assembly collide during focus and elevation calibration testing. |
||
Cause |
During focus and elevation calibration testing, to shorten the potentially lengthy testing process, we use a high drum speed. At high drum speeds, thick media may get damaged by the debris removal nozzle. |
||
Solution |
When calibrating the platesetter, make sure that the drum speed does not exceed 200 rpm. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
28 Feb 2005 |
||