Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Drum and Focus Assembly Collide During Focus and Elevation Calibration Testing of ThermoFlex Mid and Narrow


Product

 
  • ThermoFlex® Mid
  • ThermoFlex Narrow

Symptoms

 

The drum and focus assembly collide during focus and elevation calibration testing.


Cause

 

During focus and elevation calibration testing, to shorten the potentially lengthy testing process, we use a high drum speed. At high drum speeds, thick media may get damaged by the debris removal nozzle.


Solution

 

When calibrating the platesetter, make sure that the drum speed does not exceed 200 rpm.


Technical contact(s)
 

Viki Arviv

Submitted by
 

Frederic Mayot

Date submitted
 

28 Feb 2005


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.