Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


During Exposure, Interlock Errors Appear When All Doors are Closed on ThermoFlex Mid II


Product

 

Kodak ThermoFlex Mid II


Symptoms

 

During exposure, although the loading table and all doors and panels are closed, interlock errors appear, such as the Carriage cannot move because the interlock is active and the job fails. Then the system returns to Ready mode.


Cause

 

Distribution board version 3/8 malfunctions.


Solution

 

Check the version of the distribution board, and replace the board if required:

  1. In ThermoFlex Controller, in the Hardware tree, select Boards and then double-click Distribution board.
  2. In the Distribution Card dialog box, in the SoftWare area, verify the following:
    • The Version is 3.
    • The SubVer (subversion) is 8.
  3. If the Distribution board is version 3/8, replace the board with a board that has a higher subversion.


Test

 

Load a plate and close the loading table. Verify that no interlock error messages appear.


See also

 

Electronics spare part list


Technical contact(s)
 

Viki Arviv

Submitted by
 

Frederic Mayot

Date submitted
 

13 Jun 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.