Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Exposure Stops After a Software Update on ThermoFlex Mid II


Product

 

Kodak® ThermoFlex® Mid II


Error

 

This program has performed an illegal operation and will be shut down


Symptoms

 

After you update the Controller software version, during exposure, a message appears in ThermoFlex Controller:

  • Controller version 1.32.350.004 crashes.
  • Controller version 2.02.354.005, does not crash, but does not expose, and an additional message or messages regarding UDRC or vacuum appears.

Cause

 

The UDRC parameter value in the configuration setting is not correct.


Solution

 

In the Hardware tree (..\LotemFlexo\Machine …), change the UDRC Installed parameter to the the relevant value:
NONE=0, UDRC_BP = 1, UDRC_LC = 2, UDRC_BF = 3, OTHER = 4
Note: If the debris removal nozzle does not have a vacuum sensor, select 4.


Technical contact(s)
 

Viki Arviv

Submitted by
 

Trevor Ehlen

Date submitted
 

25 Oct 2007


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.