Get fails when using smart edge detection on Magnus 400 family platesetters with Magnus 400 Controller 1.01.391


Product

 
  • Kodak® Magnus™ 400 LDA family
  • Kodak Magnus 400 Quantum

Component

 

Smart edge detection board


Cause

 

COM6 port is not configured for smart edge detection.


Solution

 

Before you begin:

  1. Start the Magnus 400 Controller 1.01.391 + Update 3 software.
  2. In the Hardware tree, go to Boards, right-click Smart Plate Edge Card, and select Properties.
  3. In the Properties: Smart Plate Edge Card dialog box, change the value of the Com Driver parameter from USB to COM6, and click Apply.
  4. In the Hardware tree, go to Others, right-click Magnus400, and select Properties.
  5. In the Properties: Magnus400 dialog box, double-click +MACHINE.
  6. In the Properties: Magnus400\MACHINE dialog box, change the value of the Communicator for SED Card (USB0=0, COM6=1) parameter from 0 to 1, and click Apply.
  7. Quit the Magnus 400 Controller software, and then restart the software for the changes to take effect.

Technical contact(s)
 

Alon Davidor

Submitted by
 

Alon Davidor

Date submitted
 

15 Jun 2008


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.