Kodak® Magnus 400 |
||
Symptoms |
Horizontal lines appear on Magnus 400 platesetters with laser diode array (LDA) heads.
|
||
Cause |
Data corruption occurs if you select Rotate to Left or Rotate by 180 deg in the Kodak Xpo software when using the Kodak Magnus 400 Controller 1.02.392 or 1.03.393 software on a Magnus 400 platesetter with an LDA head and LIF data flow card (no TSP inside the computer; the data path is via the LIF card). This is a known problem, which will be resolved in the future. |
||
Solution |
Workaround: Do one of the following actions:
A software solution will be available in the future. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
21 Mar 2007 |
||