Error message 5269: Expose task failed due to stop spiral overflow on Magnus 400

.

Product

 
  • Magnus™ 400
  • Magnus 400 Xpose

Component

 
  • LIF–TSP cable connections
  • Workflow software is overloaded with other tasks.
  • LIF board
  • TSP board
  • LIF–TSP cable

Error

 

5269: continuously 20 stop spiral without data


Cause

 

A stop spiral overflow has occurred.


Solution

 

After each adjustment or part replacement, check whether the problem is resolved. If not, proceed to the next step.

  1. Verify that the cable between the LIF and the TSP boards is firmly connected.
  2. Verify that the workflow software is not overloaded by other tasks such as RIP, Preview, and so on.
    If tasks are running, wait until they finish, or close them.
  3. Run the same job again.
  4. If the problem persists, run the LIF board diagnostics tests.
    • The test passes—proceed to step 5.
    • The test fails—replace the LIF board.
  5. Run the TSP board diagnostic tests.
    • The test passes—replace the LIF-TSP cable.
    • The test fails—replace the TSP board.

 